Comparison of water sorption / solubility of Biodentine, composite resin and glass ionomer cement

J Korean Dent Assoc > Volume 57(5); 2019 > Article
The Journal of The Korean Dental Association 2019;57(5):264-268.
Published online May 31, 2019.
Biodentine과 복합레진, 글래스아이오노머의 물흡수도, 물용해도에 관한 비교 분석
이의중1, 홍정민2, 민정범3
1조선대학교 치과대학 치과보존학교실
2조선대학교 치과대학 치과보존학교실
3조선대학교 치과대학 치과보존학교실
Comparison of water sorption / solubility of Biodentine, composite resin and glass ionomer cement
Ui-Jung Lee1, Jung-Min Hong2, Jeong-Bum Min3
1Department of Conservative Dentistry, School of Dentistry, Chosun University
2Department of Conservative Dentistry, School of Dentistry, Chosun University
3Department of Conservative Dentistry, School of Dentistry, Chosun University
Abstract
Objectives
This study aimed to measure the water sorption / solubility of Biodentine, composite resin and glass ionomer cement. Materials and Methods: The materials used in this study were Biodentine(BD), Filtek Z250(FZ) and Ketac Molar(KM). Twenty disc-shaped specimens of each material were prepared of 6mm diameter and 1mm thickness. All specimens were desiccated for 24 hours and weighed(m1). After then, They were immersed in distilled water and stored at 37°C. 1 week later, They were washed with running water, wiped with absorbent paper and weighed(m2). Finally, They were dried for 24 hours and weighed(m3). Water sorption and solubility, net water uptake were calculated. Results: KM and BD showed high water sorption than FZ(P<0.05). KM and BD exhibited similar water sorption(P<0.05). BD exhibited high solubility than KM(P=0.012). BD exhibited high net water uptake than FZ(P=0.008). Conclusion: Biodentine showed higher water sorption, solubility and net water uptake than Filtek Z250 and Ketac Molar. Within limitation of this study, it is not recommended to use Biodentine for permanent restoration.
Key Words: Water sorption;Water solubility;Biodentine;Permanent restoration;