Warning: mkdir(): Permission denied in /home/virtual/lib/view_data.php on line 81

Warning: fopen(upload/ip_log/ip_log_2024-06.txt): failed to open stream: No such file or directory in /home/virtual/lib/view_data.php on line 83

Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 84
A literature review on clinical/ laboratory misfit evaluation on implant-prosthesis

J Korean Dent Assoc > Volume 56(9); 2018 > Article
The Journal of The Korean Dental Association 2018;56(9):462-478.
Published online September 30, 2018.
임플란트와 상부보철물의 임상적/실험적 부적합 평가에 관한 문헌고찰
김종회1, 조웅래2, 고경호3, 허윤혁4, 박찬진5, 조리라6
1강릉원주대학교 치과대학 치과보철학교실 및 구강과학연구소
2강릉원주대학교 치과대학 치과보철학교실 및 구강과학연구소
3강릉원주대학교 치과대학 치과보철학교실 및 구강과학연구소
4강릉원주대학교 치과대학 치과보철학교실 및 구강과학연구소
5강릉원주대학교 치과대학 치과보철학교실 및 구강과학연구소
6강릉원주대학교 치과대학 치과보철학교실 및 구강과학연구소
A literature review on clinical/ laboratory misfit evaluation on implant-prosthesis
Jong-Hoi Kim1, Woong-Rae Cho2, Kyung-Ho Ko3, Yoon-Hyuk Huh4, Chan-Jin Park5, Lee-Ra Cho6
1Department of Prosthodontics, Schoolof Dentistry, Gangneung Wonju National University
2Department of Prosthodontics, Schoolof Dentistry, Gangneung Wonju National University
3Department of Prosthodontics, Schoolof Dentistry, Gangneung Wonju National University
4Department of Prosthodontics, Schoolof Dentistry, Gangneung Wonju National University
5Department of Prosthodontics, Schoolof Dentistry, Gangneung Wonju National University
6Department of Prosthodontics, Schoolof Dentistry, Gangneung Wonju National University
Abstract
The presence of implant-prosthesis misfits can cause various complications. It is very important to detect misfits to prevent such complications. There are various evaluation methods for misfit assessment including clinical methods and laboratory in vitro methods. The clinical misfit evaluation includes radiographic analysis, visual observation, probing, Sheffield test, evaluation with disclosing materials, and screw resistance test. The laboratory in vitro evaluation method includes indirect modelling evaluation and direct metrological visualization. Of the indirect modelling methods, photoelastic stress analysis, finite element analysis, strain gauge analysis, and microbial colonization analysis were reviewed. Of the direct metrological visualization, microscopic analysis, 3-D photogrammetric analysis, coordinate measuring analysis, and radiographic analysis were reviewed. In this review, the characteristics, advantages and disadvantages of each method were evaluated.
Key Words: Implant;Prosthesis;Misfit;Direct metrological visualization;Indirect modelling method;Clinical evaluation method;Laboratory evaluation method;