J Korean Dent Assoc > Volume 55(11); 2017 > Article
Journal of Korean Dental Association 2017;55(11):766-776.
DOI: https://doi.org/10.22974/jkda.2017.55.11.002    Published online November 30, 2017.
외측연결형 임플란트 고정체의 경부 디자인이 임플란트 주위조직에 미치는 영향에 대한 전향적 예비 임상연구
배은빈1, 이소현2, 전영찬3, 강은숙4, 박상례5, 이진주6, 허중보7
1부산대학교 치의학전문대학원 치과보철학교실
2부산대학교 치의학전문대학원 치과보철학교실
3부산대학교 치의학전문대학원 치과보철학교실
4인제대학교 해운대 백병원 치과보철과
5경남정보대학교 치위생과
6부산대학교 치의학전문대학원 치과보철학교실
7부산대학교 치의학전문대학원 치과보철학교실
Effect of neck design on peri-implant tissue responses in external connection type implant : a prospective pilot clinical study
Eun-Bin Bae1, So-Hyoun Lee2, Young-Chan Jeon3, Eun-Sook Kang4, Sang-Rye Park5, Jin-Ju Lee6, Jung-Bo Huh7
1Department of Prosthodontics, School of Dentistry, Pusan National University
2Department of Prosthodontics, School of Dentistry, Pusan National University
3Department of Prosthodontics, School of Dentistry, Pusan National University
4Department of Prosthodontics, In-Je University Haeundae Paik Hospital
5Department of Dental Hygiene, Kyungnam College of Information & Technology
6Department of Prosthodontics, School of Dentistry, Pusan National University
7Department of Prosthodontics, School of Dentistry, Pusan National University
Abstract
This clinical study was conducted to evaluate the clinical effects of a concave neck of external connection type implant fixture designed for platform switching on the peri-implant tissue responses. Two types of implants with different neck designs were implanted in 20 patients. For the experimental group, the bioseal(BS) implant fixtures with 's' shaped concave profile on the neck were used, and non-bioseal(NBS) implant fixtures with a straight profile on the neck were used as control(Total of 40 implants, NBS: n = 19, BS: n=21). During the one-year period after implant placement, implant survival rate, marginal bone resorption, bleeding, plaque, and complications were evaluated. The survival rate of NBS and BS group was 94.74% and 90.48%, respectively. There was no significant difference on marginal bone resorption, bleeding and plaque between the two groups (P>.05). Within the limits of the present study, implants with a concave neck design showed similar clinical results to implants with a straight neck design on the peri-implant tissue responses. Longitudinal clinical studies are necessary to confirm more effective clinical results.
Key Words: implant neck design;platform switching;biological width;marginal bone resorption;peri-implant tissue;
TOOLS
METRICS Graph View
  • 0 Crossref
  •  0 Scopus
  • 72 View
  • 0 Download
Related articles


Editorial Office
Korean Dental Association, 257 Gwangnaru-ro, Seongdong-gu, Seoul 04802, Korea
Tel: +82-2-2024-9100   Fax: +82-2-468-4655/58   

Copyright © 2025 by Korean Dental Association.

Developed in M2PI