Warning: mkdir(): Permission denied in /home/virtual/lib/view_data.php on line 81

Warning: fopen(upload/ip_log/ip_log_2024-06.txt): failed to open stream: No such file or directory in /home/virtual/lib/view_data.php on line 83

Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 84
Early loading using tempo denture with solitary attachment system, implant supported overdenture with prefabricated bar attachment system on Mandibular edentulous patient: A case report

J Korean Dent Assoc > Volume 54(1); 2016 > Article
The Journal of The Korean Dental Association 2016;54(1):39-48.
Published online January 31, 2016.
하악 완전 무치악 환자에서 solitary attachment를 연결한 임시 보철물로 조기 부하를 가한 후, 조립식 바를 이용한 최종 임플란트 지지 피개의치 제작증례
박도현1, 이소현2, 전영찬3, 정창모4, 윤미정5, 허중보6
1부산대학교 치의학전문대학원 치과보철학교실
2부산대학교 치의학전문대학원 치과보철학교실
3부산대학교 치의학전문대학원 치과보철학교실
4부산대학교 치의학전문대학원 치과보철학교실
5부산대학교 치의학전문대학원 치과보철학교실
6부산대학교 치의학전문대학원 치과보철학교실
Early loading using tempo denture with solitary attachment system, implant supported overdenture with prefabricated bar attachment system on Mandibular edentulous patient: A case report
Do-Hyeon Park1, So-Hyoun Lee2, Young-Chan Jeon3, Chang-Mo Jeong4, Mi-Jung Yun5, Jung-Bo Huh6
1Department of Prosthodontics, School of Dentistry, Pusan National University
2Department of Prosthodontics, School of Dentistry, Pusan National University
3Department of Prosthodontics, School of Dentistry, Pusan National University
4Department of Prosthodontics, School of Dentistry, Pusan National University
5Department of Prosthodontics, School of Dentistry, Pusan National University
6Department of Prosthodontics, School of Dentistry, Pusan National University
Abstract
SFI-bar is prefabricated bar system and can be assembled at chairside without soldering or welding, thus reducing bone loss, costs and time. A 53-year-old male patient, who had severely absorbed mandible, hoped to wear a stable mandiblular denture. Four implants were placed in the extraction site of canine and 1st molar. Early loaded temporary denture with solitary type attachment was delivered 3 weeks after surgery. 3 month later, SFI-bar was connected and adjusted at chairside. Then, implant overdenture using SFI-bar was delivered. This case report showed that a satisfactory clinical result was achieved by 4-implant-supported overdenture using the SFI-Bar system in a mandibular edentulous patient.
Key Words: Early loading;Implant-supported overdenture;Prefabricated bar;SFI-bar;
TOOLS
METRICS Graph View
  • 2 View
  • 0 Download
Related articles


Editorial Office
Korean Dental Association, 257 Gwangnaru-ro, Seongdong-gu, Seoul 04802, Korea
Tel: +82-2-2024-9100   Fax: +82-2-468-4655/58   

Copyright © 2024 by Korean Dental Association.

Developed in M2PI