Warning: mkdir(): Permission denied in /home/virtual/lib/view_data.php on line 81

Warning: fopen(upload/ip_log/ip_log_2024-06.txt): failed to open stream: No such file or directory in /home/virtual/lib/view_data.php on line 83

Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 84

J Korean Dent Assoc > Volume 44(2); 2006 > Article
The Journal of The Korean Dental Association 2006;44(2):115-122.
Published online February 28, 2006.
자가 치아 이식술에 사용되는 Computer Aided Rapid Prototyping model(CARP model)의 실제 치아에 대한 오차
이성재1, 김의성2, 김기덕3, 이승종4
1일산예치과ㆍ연세대학교 치과대학 치과보존학교실
2연세대학교 치과대학 치과보존학교실
3연세대학교 치가대학 구강악안면방사선학교실
4연세대학교 치과대학 치과보존학교실
Seong-Jae Lee1, Ui-Seong Kim2, Gi-Deok Kim3, Seung-Jong Lee4
Abstract
Objective
: The purpose of this study was to evaluate the dimensional errors between real tooth, 3D CT image and CARP model. Materials and Methods : Two maxilla and two mandible block bones with intact teeth were taken from two cadavers. Computed tomography was taken either in dry state and in wet state. After then, all teeth were extracted and the dimensions of the real teeth were measured using a digital caliper at mesio-distal and bucco-lingual width both in crown and cervical portion. 3D CT image was generated using the V-works 4.0TM (Cybemed Inc., Seoul, Korea) software. Twelve teeth were randomly selected for CARP model fabrication. All the measurements of 3D Ct images and CARP models were made in the same manner of the real tooth group. Dimensional errors between real tooth, 3D CT image model and CARP model was calculated. Results : 1) Average of absolute error was 0.199 mm between real teeth and 3D CT image model, 0.169 mm between 3D CT image model and CARP model and 0.291 mm between real teeth and CARP model, respectively. 2) Average size of 3D CT image was smaller than real teeth by 0.149 mm and that of CARP model was smalier than 3D CT image model by 0.067mm. Conclusion : Within the scope of this study, CARP model with the 0.291 mm average of absolute eror can aid to enhance the success rate cf autogenous tooth transplantation due to the increased accuracy of recipient bone and donor tooth.
Key Words: Absolute error;Autotransplantation;Donor tooth;Rapid prototyping;Recipient bone site preparation;
TOOLS
METRICS Graph View
  • 2 View
  • 2 Download
Related articles


Editorial Office
Korean Dental Association, 257 Gwangnaru-ro, Seongdong-gu, Seoul 04802, Korea
Tel: +82-2-2024-9100   Fax: +82-2-468-4655/58   

Copyright © 2024 by Korean Dental Association.

Developed in M2PI