Hanau 96-H₂교합기에 상악 모형 부착시 교합면 경사각에 대한 비교 연구 |
황희성1, 이호용2 |
1연세대학교 치과대학 보철학교실 2연세대학교 치과대학 보철학교실 |
A Comparative Sudy on Accuracy of Occlusal Plane Angle on Mounting The Hanau 96-H2 Articulator |
Hie-Seong Hwang1, Ho-Yong Lee2 |
1Dept. of Prosthodontics, College of Dentistry, Yon Sei University 2Dept. of Prosthodontics, College of Dentistry, Yon Sei University |
|
Abstract |
The Purpose of this study was to know the differences between the occlusal plane angles formed by F-H plane on cephalograms and the occlusal plane angles by the upper margin of the articulator, and to ind the contributing factors to the difference of occlusal angles. for this study, 39 young adults (20 men, 19 women) were selected who had normal occlusion, no severe attrition, no missing tooth, not been under orthodontic treatment and occlusal equilibration and no temporomandibular disorders. The maxillary casts were mounted with Hanau 159-1 ear piece type face-bow and measured the occlusal plane angle with prototype occlusal plane projector. The following results were obtained; 1. The mean value of the ear rod F-H plane occlusal angle was 14.75˚, articulator occlusal angle was 9.26˚ and strong positive correlation between these angles, 2. It was almost same angle between the ear rod F-H plane angle (14.75˚) and the beyron point to infraorbital rim-6mm. occlusal angle (14.46˚) 3. The mean distance from the ear rod porion to the Byron point was 5.67mm. 4. It was no significant correlation between the distances Po-Beyron point, Or-infraorbital rim and articulator occlusal angle. |
|